Place of Origin:
CHINA
Brand Name:
SolarEast
Certification:
TUV,SG Ready,CE,KEYMARK,BAFA
Model Number:
BLN-014TB1;BLN-014TB3
Contact Us
6KW Geothermal Heating And Cooling A+++ Heat Pump Boiler
Model |
BLN-014TB1; BLN-014TB3 |
||
Power Supply | V/Ph/Hz |
220~240/1/50; 380~415/3/50 |
|
Nominal Heating (Max) (A7/6℃, W30/35℃) |
Heating Capacity | kW | 5.30~16.60 |
Power Input | kW | 1.15~4.15 | |
COP | W/W | 3.97~5.43 | |
Nominal Heating (Max) (A7/6℃, W47/55℃) |
Heating Capacity | kW | 4.90~15.10 |
Power Input | kW | 1.65~5.25 | |
COP | W/W | 2.87~3.38 | |
Nominal Cooling (Max) (A35/24℃, W12/7℃) |
Cooling Capacity | kW | 4.40~13.50 |
Power Input | kW | 1.45~13.50 | |
EER | W/W | 2.87 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | |
ERP Level(Outlet water temp. at 55℃) | / | A++ | |
Rated input power | kW | 6.20 | |
Rated input current | A | 27.5;10.50 | |
Refrigerant /Charge/GWP | / | R32/2.8/675 | |
Rated water flow | m³/h | 2.52 | |
Fan quantity | / | 1 | |
Fan motor type | / | DC inverter | |
Compressor | / | Panasonic / DC inverter / Rotary / EVI | |
Circulating pump | / | Inverter type / Built-in | |
IP Class | / | IPX4 | |
Sound pressure at a 1m distance | dB(A) | 53-55 | |
Max outlet water temperature | °C | 60 | |
Water piping connections | / | G1-1/4 | |
Pressure drop at rating water flow | kPa | 30 | |
Operating temperature range (Heating mode) | °C | -25~45 | |
Operating temperature range (Cooing mode) | °C | 16~45 | |
Unpacked Dimensions ( L×D×H ) | mm | 1100×480×850 | |
Packed Dimensions ( L×D×H ) | mm | 1150×565×1000 | |
UnPacked Weight | kg | 124 | |
Packed Weight | kg | 136 |
The performance of typical heat pumps will be constrained in low ambient temperatures.
First, when it comes to heating capacity, lower ambient temperatures result in lesser heating capacity. Second, the stability of the machine and the operation's dependability would be impacted by the low temperature environment. Third, the heat pump's performance will be impacted by the operating breadth and safety range.The Three-in-One 290 heat pump, however, can function effectively at -25°C while maintaining a high COP and consistent stability.
Equipped with the DC inverter brushless fans and designed based on aerodynamics, SolarEast DC inverter heat pumps adopt multiple noise reduction and sound insulation measures so that noise is reduced to a low level. The sound levels start as low as 50 dBA.
The unit can operate at a high frequency to heat water at a faster speed. When the temperature reaches the set temperature, it will operate at a low frequency with less energy consumed to maintain temperature.
SUNRAIN's self-developed online intelligent remote control system. The system has highly integrated control functions and can be operated by a remote APP. With simple operation and stable performance, it is truly intelligent. The operating system realizes the separation of man and machine.
Send your inquiry directly to us