Place of Origin:
CHINA
Brand Name:
SUNRAIN
Certification:
TUV
Model Number:
BLN-014TB1
Contact Us
Model | BLN-014TB1 | BLN-014TB3 | ||
Power Supply | V/Ph/Hz | 220~240/1/50 | 380~415/3/50 | |
Nominal Heating (Max) (A7/6℃,W30/35℃) |
Heating Capacity | kW | 14.45 (5.30-16.50) | 14.45 (5.30-16.60) |
Power Input | kW | 1.15-4.15 | 1.15-4.15 | |
Power Current | A | 5.10 ~ 18.41 | 1.86-6.70 | |
COP | W/W | 3.97-5.43 | 3.97-5.43 | |
Nominal Heating (Max) (A7/6℃,W47/55℃) |
Heating Capacity | kW | 4.90-15.10 | 4.90-15.10 |
Power Input | kW | 1.65-5.25 | 1.65-5.25 | |
Power Current | kW | 7.32-23.30 | 1.67-8.47 | |
COP | W/W | 2.87-3.38 | 2.87-3.38 | |
Nominal Cooling (Max) (A35/24℃,W12/7℃) |
Cooling Capacity | kW | 4.50-13.50 | 4.50-13.5 |
Power Input | kW | 1.45-4.85 | 1.45-4.85 | |
Power Cunrrent | A | 6.43-21.52 | 2.34-7.82 | |
EER | W/W | 2.87 | 2.87 | |
ERP Level(Outlet water temp. at 35℃) | / | A+++ | A+++ | |
ERP Level(Outlet water temp. at 55℃) | / | A++ | A++ | |
Rated input power | kW | 6.20 | 6.20 | |
Rated input current | A | 27.50 | 10.50 | |
Refrigerant Type / Charge / GWP | / | R32/2.8/674 | R32/2.8/675 | |
Rated water flow | m3/h | 2.52 | 2.52 | |
Fan quantity | / | 1 | 1 | |
Fan motor type | / | DC inverter | ||
Compressor | / | Panasonic / DC inverter / Rotary / EVI | ||
Circulating pump | / | Inverter type / Built-in | ||
IP Class | / | IPX4 | ||
Sound pressure at 1m distance | dB(A) | 53 | 55 | |
Max outlet water temperature | °C | 60 | 60 | |
Water piping connections | / | G1-1/4 | G1-1/4 | |
Pressure drop at rating water flow | kPa | 30 | 30 | |
Operating temperature range (Heating mode) | °C | -25~45 | ||
Operating temperature range (Cooing mode) | °C | 16~45 | ||
Unpacked Dimensions ( L×D×H ) | mm | 1110×480×850 | 1110×480×850 | |
Packed Dimensions ( L×D×H ) | mm | 1160×565×1010 | 1160×565×1010 | |
UnPacked Weight | kg | 124 | 124 | |
Packed Weight | kg | 136 | 146 |
A SolarEast intelligent defrosting mode calculates the difference in temperature between the evaporator and the compressor and calculates how long the compressor has been working to determine whether the evaporator is defrosting. Automatically, the defrosting mode will be entered when the defrosting condition is met.
In particular, the strength of the factory.
Over 100,000 square meters are occupied by the plant of Solareast Heat Pump Ltd. Our facility has an amazing annual production capability of 50,000 heat pump units.In accordance with the ISO9001, ISO13485, BSCI, SGS, and EPA requirements, our business built a quality management system. There are certifications for products like KEYMARK, BAFA, MCS, UKCA, CE, CB, ROHS, and ETL.
We provide comprehensive solutions for numerous sectors through our four specialized laboratories. Our testing capabilities cover a wide temperature range, from a freezing -35°C to a sweltering 50°C, guaranteeing accurate evaluations under various environmental circumstances. Additionally, with the capacity to accommodate machines with up to 120 horsepower, our lab is set up to handle equipment of tremendous power. Each laboratory has a particular area of expertise, with the A3 lab serving pool units, the B1 lab concentrating on all-in-one heat pump water heaters, the A2 lab testing monoblock heat pumps, and the A1 lab catering to commercial units. We are dedicated to providing accurate and trustworthy results, assisting our clients in achieving peak performance and product quality assurance.
Send your inquiry directly to us